The Gas Safety Burner, The Bunsen Burner

The perfected Bunsen burner

  • Made of stainless steel and glass
  • Digital display of burn-time
  • Digital status display
  • Up to 80% gas savings
  • UV-resistant, may be flame-sterilized
  • Adustable in the continous mode for up to 99 minutes
  • For laboratory and mobile operation
  • Robust and highly reliable

Acvivate by moving your hand in front of the display or by using the foot-switch:

Sensor operation
The user may individually set the sensitivity of the IR-Sensor (touch free) in order to activate the burner with the movement of a hand or the tip of a pipette/inoculating loop. The gas supply automatically cuts off when the present time randing from 1 sec to 99 min has elapsed and the flame stops.

Sensor distance (0-80mm)
The distance is digitally and continously adjustable in 32 individual steps.

Foot-switch, mode 1
Gas supply and electronic ignition are activated automatically. The flame only comes on when pressing the foot-switch and is thereby permanently under control. As soon as the foot-switch is released, the gas supply is cut off and the flame stops immediately.

Foot-switch, mode 2
The flame comes on when pressing the foot-switch once and stops after pressing the foot-switch again or the preset time has elapsed.


Safety

Flame monitoring
Shold the flame inadvertently extinguish, a safety feature will provide for automatic re-ignition without interupting your work.

Ignition monitoring
The gas supply automatically cuts off as soon as the automatic re-ignition fails for more than 10 seconds to produce a flame. The digital display shows the corresponding fault report.

Continuous flame supervision
Should the flame extinguish due to spilled liquids and cannot be re-ignited, the gas supply automatically cuts off. The digital display shows the corresponding fault report.

Precisely adjustable burn-time
Digital and exact to the second (1 sec...99 min), safety cut-off after 99 mins. Turning the malfunction control to the left hand side decreases the burn-time, turning to the right causes an increase. The present time is stored until the setting is changed again (memory function).

Products we carry

Manual pipettesSpecial pipettes
Bottle Top DispensersSyringes / Repeaters
Pipette FillersElectronic Balance
SpectrophotometerGlassware
Plastic consumablesCapilary tubes
Haematocrit tubesTransport Swabs
Dehydrated Culture MediaFilter Paper
Microslides / Cover GlassOrganic Chemicals
BurnersUV Products
Bio Imaging SystemsOven / Waterbaths
IncubatorShakers
Pumps / TubingRotary Evaporators
Reference StandardsHPLC Columns / Syringes
Pre Poured PlatesTransport Swabs
Hotplate / Magnetic StirrerVortex Mixers
Laminar Flow CabinetCytotoxic Drug Safety Cabinet
Particle ScannerAir Sampler
Colony Counter

Useful links

About Us
Location MapRecruitment